Return to home page Return to home page
Stalker Stationary Speed and Traffic Statistics Sensor Stalker Low Speed Sensor Stalker Traffic Statistics App Stalker 6x26 degree sensors

Hump Yard (Analog) Sensor

How to choose Sensors

Designed for Railroad Hump Yard applications
where accuracy matters

Stalker Traffic Control Sensor

Analog output signal frequency is proportional to target speed.

RS-232 used for configuration.

Output frequency is 0.01389 Hz/mph (0.0222 Hz/km/h) (44.72 Hz/km/h).

  • MPH, km/h, knots, m/s, ft/s
  • RS-232 configuration
  • Analog output
  • IP67 rated
  • 1-Year parts and labor warranty
Part Number Description  
200-1135-50 Rear Port RS-232

 






 

 

 

 

  • SPECIFICATIONS
  • ACCESSORIES
  • DOWNLOADS

Performance:

Max Range >1300 Feet (400 m)
Min Speed 1 MPH (1.6 km/h)
Max Speed 200 MPH (321.9 km/h)
Speed Accuracy

+/-3% (+/- 0.8 km/h +/-3% )

Isolated Bi-polar outputs, +/- 12 volt pp max
Fixed gain or automatic gain control modes

Power:

Voltage

10 to 22 volts, DC

Current 210 mA @ 12 VDC typical
Power 2.5 watt
Protections Transient protection
Reverse voltage protection
Resettable Fuse

Microwave:

Center frequency 24.125 GHz
Frequency Span 100 MHz
Transmit Power 100 mW
Beam Width 30° by 32°
F.C.C. Approved. No license required.

Physical Specifications:

Size (LxWxD) w/o connector 4.4 x 3.9 x 1.6 inches (11.2 x 9.9 x 4 cm)
Weight <13 oz. (.35 kg)
Housing Die-cast aluminum
Lens HDPE
Electrical connector M12, 12 pin
Mounting 4 x 10-32 UNF

Environmental:

Operating temp. -22° F (-30° C) to +185° F (+70° C)
Storage temp. -40° F (-40° C) to +185° F (+85° C)
Ingress rating IP67

Brochure Downloads

Stalker Sensor Family Brochure

 

Manual Downloads

Stalker Hump Yard Sensor Manual